When setting up an Active Directory environment, machines sometimes do not sync time with the closest DC or, worse, when a DC and a server sync time, causing massive time drift.
When the script below is applied to the domain-level OU, workstations and servers will sync their time with the local DC(s). The DCs will sync with the PDC emulator, which will sync with Us.pool.ntp.org
You can click here if you’d like to learn how to apply the PowerShell script to a group policy.
If you have any questions, please fill out the comment section at the end of this post, and we will get back to you.


Full Script
Modifications:
Line 4: if you choose to use something other than Us.pool.ntp.org
Trouble Shooting:
Line 51: Will give you the time source the computer will use.
Line 54: Will give you more information about the sync.
#The goal for this script is to set the time for all devices. For Workstations and Non-Domain COller Servers, the device time will point to the local DC
#For Domain Collers that do not have the PDC role, they will point to the PDC server.
#For The PDC server we are pointing our time to an external source
$timeSource = "Us.pool.ntp.org"
#Stopping the time server
net stop w32time
w32tm /unregister
w32tm /register
net start w32time
#gets the product IT
$ProdcutType = Get-CimInstance -Class Win32_OperatingSystem | select ProductType
#1 is for workstations and 3 is not non-domain controller servers
if($ProdcutType.ProductType -eq 1 -or $ProdcutType.ProductType -eq 3)
{
#Point to the local Domain Controller
w32tm /config /syncfromflags:domhier /update
} else {
#We are finding the PDC server
= Get-ADForest |
Select-Object -ExpandProperty RootDomain |
Get-ADDomain |
Select-Object -Property PDCEmulator |
Select-Object -ExpandProperty PDCEmulator
#Gets the device FQDM
$localhostname = hostname
$domain = Get-WmiObject -Namespace root\cimv2 -Class Win32_ComputerSystem | Select Domain
$fqdm = $localhostname + "." + $domain.Domain
#If we are not the PDC Emulator
if($fqdm -ne $PDC)
{
#Set time to the PDC
w32tm /config /manualpeerlist:$PDC /syncfromflags:manual /reliable:yes /update
} else{
#Set time to the external source
w32tm /config /manualpeerlist:"$timeSource,0x8" /syncfromflags:manual /reliable:yes /update
}
}
#Stop and start time service again
net stop w32time
net start w32time
w32tm /resync /nowait
#Gets who the computer is syncing with. If script just ran, it might say "Local CMOS Clock", wait a minute and try again.
#w32tm /query /source
#Last line is if we need to get more info
#w32tm /query /status